TEC.GPMB - Bearing Point Grease Pulse Meter
TEC.GPMB - Bearing Point Grease Pulse Meter
TEC.GPMB - Bearing Point Grease Pulse Meter
The Tecalemit Grease Pulse Meter monitors grease flow into critical bearing points protecting them from premature failure.
Installed directly onto the inlet of the bearing and connected to the customer PLC, if the bearing point does not receive the required amount of grease in the correct time period an alarm can be raised to prevent bearing failure and down time.
The metering system is based on a measuring chamber that contains two oval gears. When rotating the pulse signal is monitored by the PLC.
The gears are made to turn by the fluid flowing through the chamber. The volume of fluid that flows through is calculated by the number of gear rotations, given that each rotation corresponds to the identical amount of fluid.
By calibrating the PLC, the pulsed signal is converted into the amount of grease that has been dispensed.
Technical Specifications.
Product: Grease Grade 000 - 2
Operating Range: 7250 psi, 500 Bar
Signal Type: Reed Switch
Flow: 0.1 - 2.5 L/min
Pulses per Litre: 1400 (1,400 cc) nominal
Surface Protection: Aluminium Anodised
Electrical Protection: IP65
Mass: 0.6 KG
Size: 70L x 75H x 46W mm
Operating Temperature: - 25 - 85ºC
Inlet Port: 1/8” BSP Female
Outlet Port: 1/8” BSP Female
Electrical Connection: M12 x 1, 4 pin
Pin 1: + VE Brown
Pin 2: - VE White
Max Current: 100mA
Max Voltage: 28V AC/DC
Extras
TEC.GPMB: Pulse Meter (No Cable)
PT.CABLE: Plug and 2m Cable
PT.CABLE.5M: Plug and 5m Cable